top of page
PROJECTS GALLERY
Explore Our Portfolio: Residential, Commercial Spaces, and Industrial Projects
Discover Our Engineer-Stamped Design & Permit Drawings
We specialize in designing and engineering structures, providing permit drawing sets, conducting condition assessments, managing construction projects, and serving as expert engineers in disputed cases.
Please note that we are structural engineers and not contractors.
Commercial Projects
Roof Steel Joist Evaluation
Structural Analysis:
Pittsburgh Design & Engineering Services mapped/measured the existing roof steel truss system to evaluate its structural integrity to support load applied due to potential Fall restraint system while electrical contractor replacing electrical switchgear. Load applied as recommended by OSHA for such application and stamped approved letter with calculation set provided for the contractor to submit for the record.
Project located at Pittsburgh International Airport, Central Services Building.
Pittsburgh Design & Engineering Services mapped/measured the existing roof steel truss system to evaluate its structural integrity to support load applied due to potential Fall restraint system while electrical contractor replacing electrical switchgear. Load applied as recommended by OSHA for such application and stamped approved letter with calculation set provided for the contractor to submit for the record.
Project located at Pittsburgh International Airport, Central Services Building.
Steel Plates Verification
Verified existing floor steel plates can support the weight of scissor lift based on scissor size and specification as well steel plates dimension & thickness.
Project Located at Pittsburgh International Airport
Project Located at Pittsburgh International Airport
Fire Damage Evaluation/Assessment
Review and evaluate the structural integrity of the impacted structural members due to a fire damage.
Corroded and Damaged Steel Floor Joists
Requested to evaluate Corroded and Damaged Steel Floor Joists. This damage was discovered upon removal of finished ceiling panels, it was due to excessive condensation, lack of proper insulation and leak from upper level drain.
Rust and partially corroded steel decking
Requested to evaluate floor structure. This damage was discovered upon removal of finished ceiling panels, it was due to excessive condensation, lack of proper insulation and leak from upper level drain.
PNC Scoreboard
Pittsburgh Design & Engineering Services conducted a specialized inspection of the PNC Scoreboard to ensure compliance with the design and drawings provided by the Engineer of Record (EOR). This encompassed a detailed examination of brackets, framing, and their attachment to the main structure, as stipulated by the City of Pittsburgh permitting office
PNC Scoreboard Inside
Pittsburgh Design & Engineering Services conducted a specialized inspection of the PNC Scoreboard to ensure compliance with the design and drawings provided by the Engineer of Record (EOR). This encompassed a detailed examination of brackets, framing, and their attachment to the main structure, as stipulated by the City of Pittsburgh permitting office.
Residential Projects
Sample Calculations for Load Bearing Beam Laminated Veneer Lumber (LVL)
All of our stamped drawings for load bearing wall(s) removal and replacement with Laminated Veneer Lumber (LVL) are always supported with calculations report.
Horizontal Crack-Bow in Foundation Wall
Sample Permit Drawings for Load bearing Wall Removal and Replacement With LVL
Sample Site Plan Drawings for the City of Pittsburgh
We offer site plan stamped drawings services for your zoning requirement in the state of Pennsylvania.
Over 4" Bow in Terracotta Foundation Wall
Foundation Repair for West Homestead Multi Unit Residential Building
Old Terracotta Wall Needed to be Rebuilt
We offered foundation design permit drawings to repair existing foundation wall that was damaged/leaning for West Homestead Multi Unit Residential Building
New Wall to Replace Old Terracotta Wall
We offered foundation design permit drawings to repair existing foundation wall that was damaged/leaning for West Homestead Multi Unit Residential Building
Foundation Plans
Foundation Walls For a House in Mexican War Street that Required Reinforcement
New Foundation Section Cut
Foundation Walls For a House in Mexican War Street that Required Reinforcement
Elevation Section Detail
Foundation Walls For a House in Mexican War Street that Required Reinforcement
Joist Details
Foundation Walls For a House in Mexican War Street that Required Reinforcement
Corroded Structural Steel I-Beam in a Residential Basement
Water can cause a lot of damage and here is an example of what it can do to structural steel when it isn't controlled. In this case we had about 25-50% material loss.
bottom of page